Product

โบลเวอร์ความดันต่างสูง Gardner Denver G-2BH7

ความดันต่างสูงสุด 1,000 mbar ทำงานได้ถึง 20,000 ชั่วโมงระหว่างการบำรุงรักษา

Model: G-2BH7
ดู Enquiry list

Not sure about the model? Send us the working conditions — flow rate, pressure or vacuum level, media and voltage — and we will confirm the right unit.

Technical description

The G-2BH7 side channel blower reaches a differential pressure up to 1,000 mbar. Systems that need this pressure range have traditionally been noisy, bulky or prone to wear; the G-2BH7 combines wear-free running with a low noise level and stays usable in demanding applications.

As a vacuum pump or compressor it can run up to 20,000 hours without a maintenance stop. IE2 motor versions are available on request.

ParameterValue
SeriesGardner Denver G-2BH7
TypeSide channel blower, high differential pressure
Differential pressureup to 1,000 mbar
StagesSingle or multi-stage
Maintenance intervalup to 20,000 hours
Frequency50 / 60 Hz
ProtectionIP55
Motor optionIE2 available on request

Key features

  • Wear-free operation with a low noise level
  • Differential pressure up to 1,000 mbar
  • Up to 20,000 hours between maintenance stops
  • G-BH8 variant with the best power-to-weight ratio, -550 to +720 mbar, IE3 motors

Typical applications

  • Chemical and petrochemical process duty
  • Fluid bed drying and coating
  • Glass tempering quench air
  • Dense phase pneumatic conveying

Model selection

Flow, differential pressure and motor rating depend on the impeller stage and the motor fitted. Send us the duty point — required flow, pressure or vacuum level, conveyed media, temperature, voltage and area classification — and we will confirm the exact model, stage count and motor.

Supply scope

  • Complete unit with motor, mounting feet and terminal box
  • Inlet and outlet silencers, filters and flexible connectors available
  • Spare parts, seals, impellers, bearings and wearing parts held for after-sales
  • Documentation, wiring diagram and commissioning guidance supplied with the unit

Related